- Descrizione macchina:
- Camera climatica Memmert ICH 750
- Produttore:
- Memmert
- Modello:
- ICH 750
- Anno di produzione:
- 2022
- Condizione:
- come nuova (usata)
Prezzo e posizione
Prezzo fisso IVA esclusa
14.000 €
- Ubicazione:
- ul Narutowicza 44-10, 99-320 Żychlin, PL
Chiama
Dettagli dell'offerta
- ID dell'annuncio:
- A19993820
- Ultimo aggiornamento:
- il 14.09.2025
Descrizione
Memmert ICH 750 chamber from 2022, originally packaged and tested, condition as new, one year warranty on spare parts.
Temperature
Set temperature range: -10 to +60 °C
Operating temperature range: from -10°C to +60°C without humidity (not suitable for long-term storage at sub-zero temperatures. During continuous operation, glass doors may become frosted)
Operating temperature range: from +10°C to +60°C with humidity and/or light
Temperature setting accuracy: 0.1 °C
Temperature sensor: 2 x Pt100 sensors in DIN A class, 4-wire system, mutually monitoring and taking over functions in case of failure
Humidity
Humidity supply: distilled water supply from an external tank via self-priming pump
Humidification: humidification via steam generator
Humidity: active humidification and dehumidification adjustable in the range of 10–80 % rh with digital display of relative humidity – display resolution 0.1 %, setting accuracy 0.5 %
Control technology
ControlCOCKPIT
TwinDISPLAY. Adaptive, multifunctional digital PID microprocessor controller with two high-resolution TFT color displays.
Adjustable parameters: temperature (°C or °F), fan speed, relative humidity, program time, time zones, daylight saving time
Language settings: German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese
Timer: Digital countdown timer with target time setting, adjustable from 1 minute to 99 days
SetpointWAIT function: process time does not start until the set temperature is reached
Calibration: up to three user-selectable values for temperature/humidity and two values for CO₂
Gjdpfxsxcgh Re Ag Rskc
Ventilation
Fan: forced air circulation in the working chamber, adjustable from 10–100 % in 10 % increments
Communication
Documentation: program stored in case of power failure
Programming: AtmoCONTROL software on USB drive for programming, managing, and transferring programs via Ethernet interface or USB port
Safety
Temperature control: mechanical temperature limiter TB, safety class 1 according to DIN 12880, switches off heating approx. 10 °C above set temperature
Temperature control: TWW over- and under-temperature monitor, safety class 3.3, or TWB adjustable temperature limiter, safety class 2, selectable from the display
AutoSAFETY: integrated over- and under-temperature protection system "ASF", automatically follows set value within predefined tolerance range, alarm if exceeded or below; in case of overheating, heating is switched off, in case of underheating – compressor
Self-diagnostic system: integrated error diagnostics for temperature and humidity control
Alarm: visual and acoustic
Heating concept
Air jacket: air jacket heating system for gentle, even warming
Heating concept: no sample drying by the cooling device due to separation of heating jacket from the chamber interior
Cooling: energy-saving cooling/heating system without CFCs. Refrigerant R 134A
Defrosting: high-performance automatic defrosting system
Standard equipment
Factory calibration certificate: standard values at +10 °C and +37 °C, 60 % rh at +30 °C
L'annuncio è stato tradotto automaticamente e possono essersi verificati degli errori di traduzione.
Temperature
Set temperature range: -10 to +60 °C
Operating temperature range: from -10°C to +60°C without humidity (not suitable for long-term storage at sub-zero temperatures. During continuous operation, glass doors may become frosted)
Operating temperature range: from +10°C to +60°C with humidity and/or light
Temperature setting accuracy: 0.1 °C
Temperature sensor: 2 x Pt100 sensors in DIN A class, 4-wire system, mutually monitoring and taking over functions in case of failure
Humidity
Humidity supply: distilled water supply from an external tank via self-priming pump
Humidification: humidification via steam generator
Humidity: active humidification and dehumidification adjustable in the range of 10–80 % rh with digital display of relative humidity – display resolution 0.1 %, setting accuracy 0.5 %
Control technology
ControlCOCKPIT
TwinDISPLAY. Adaptive, multifunctional digital PID microprocessor controller with two high-resolution TFT color displays.
Adjustable parameters: temperature (°C or °F), fan speed, relative humidity, program time, time zones, daylight saving time
Language settings: German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese
Timer: Digital countdown timer with target time setting, adjustable from 1 minute to 99 days
SetpointWAIT function: process time does not start until the set temperature is reached
Calibration: up to three user-selectable values for temperature/humidity and two values for CO₂
Gjdpfxsxcgh Re Ag Rskc
Ventilation
Fan: forced air circulation in the working chamber, adjustable from 10–100 % in 10 % increments
Communication
Documentation: program stored in case of power failure
Programming: AtmoCONTROL software on USB drive for programming, managing, and transferring programs via Ethernet interface or USB port
Safety
Temperature control: mechanical temperature limiter TB, safety class 1 according to DIN 12880, switches off heating approx. 10 °C above set temperature
Temperature control: TWW over- and under-temperature monitor, safety class 3.3, or TWB adjustable temperature limiter, safety class 2, selectable from the display
AutoSAFETY: integrated over- and under-temperature protection system "ASF", automatically follows set value within predefined tolerance range, alarm if exceeded or below; in case of overheating, heating is switched off, in case of underheating – compressor
Self-diagnostic system: integrated error diagnostics for temperature and humidity control
Alarm: visual and acoustic
Heating concept
Air jacket: air jacket heating system for gentle, even warming
Heating concept: no sample drying by the cooling device due to separation of heating jacket from the chamber interior
Cooling: energy-saving cooling/heating system without CFCs. Refrigerant R 134A
Defrosting: high-performance automatic defrosting system
Standard equipment
Factory calibration certificate: standard values at +10 °C and +37 °C, 60 % rh at +30 °C
L'annuncio è stato tradotto automaticamente e possono essersi verificati degli errori di traduzione.
Venditore
Nota: Registrati gratuitamente o accedi, per visualizzare tutte le informazioni.
Registrato da: 2019
Invia richiesta
Telefono & Fax
+48 793 1... mostra
Il tuo annuncio è stato cancellato con successo
Si è verificato un errore